Updated Nov 2026·4 min read·Ramadi Group, Dubai

Before you reset

A reset clears the control electronics; it does not fix a mechanical fault. Do it when the screen is frozen, buttons do not respond, a cooking program will not start, or a service message stays on after the cause is fixed. Do not reset while the cabinet is above 100°C with the door closed; let it cool to be safe.

Step 1 — Soft restart from the panel

  1. On iCombi Pro/Classic: press and hold the power/standby button on the top left of the display for about 5 seconds until the screen goes dark.
  2. Wait 30 seconds.
  3. Press the button again. The unit boots, runs a short self-test and shows the home screen.

On SelfCookingCenter (SCC) whitefficiency units, the on/off switch is the illuminated button on the control panel; hold it until the display switches off, wait, then switch on.

Step 2 — Hard reset at the isolator

If the panel does not respond at all, switch the unit off at its wall isolator or circuit breaker, wait 60 seconds so the capacitors on the control board discharge, then switch back on. Let the self-test finish before touching the screen.

Step 3 — Clear a service message

Many service codes clear themselves once the cause is removed (door closed, water supply on, filter replaced). If a code returns after a reset it is a real fault, not a software glitch. Note the exact code; see our Rational error code guide for what the common ones mean.

Step 4 — Check the basics

  • Water supply open, pressure 1.5–6 bar, filter not blocked.
  • Drain not blocked and air gap clear.
  • Door microswitch: the door must register as closed.
  • Core probe plugged in correctly (a damaged probe often blocks program start).
  • Gas units: gas supply open and the unit not in a lockout after a failed ignition.

When to call service

Call us if the unit will not power on at the isolator, the same code returns after two resets, the display is cracked or dark, there is a burning smell, or a gas unit repeatedly fails ignition. Ramadi Group services Rational ovens across Dubai, Abu Dhabi and Sharjah and keeps door gaskets, lamps, solenoid valves, pumps, probes and control boards available to order. WhatsApp us the model and serial number from the plate under the door.

Frequently asked questions

Will a reset delete my cooking programs?

No. A power cycle does not delete saved programs. Only a factory reset in the settings menu does, and that asks for confirmation.

The oven starts but shows 'Service' every few minutes.

That is a stored fault, usually water-related (pressure, inlet, drain) or a sensor. Note the number after 'Service' and compare it with our error-code guide, then call if it persists.

Can I keep cooking with a service code showing?

Some codes allow limited operation (for example care-tab warnings). Codes about temperature sensors, gas or the steam generator stop the unit for safety; do not bypass them.

Need help in Dubai?

Call +971 4 884 0555 or send us your requirements — we reply with options.