How Rational shows faults
Rational units show faults as Service followed by a number (e.g. Service 25). The number groups the fault by subsystem. Exact meanings differ slightly between SelfCookingCenter, iCombi Classic and iCombi Pro generations, so treat the table below as the usual cause and confirm with the model's service documentation or our technicians.
Common codes and what they usually mean
| Code | Area | Usual cause | Typical fix / part |
|---|---|---|---|
| Service 10 | Automatic cleaning / SC | Cleaning cycle interrupted or water quality | Restart cleaning; check water supply and tabs |
| Service 11 | Steam / humidity control | Humidity sensor or steam generation reading out of range | Humidity/temperature sensor, control board check |
| Service 12 | Cabinet temperature sensor | Sensor open or short circuit | Cabinet temperature probe (B1) |
| Service 14 | Steam generator sensor | Steam generator temperature sensor fault | Steam generator probe |
| Service 20 | Steam generator | Generator not filling or level fault | Inlet solenoid valve, level electrode, descale |
| Service 23 | Steam heating | Steam generator not reaching temperature | Steam heating element, contactor |
| Service 25 | Water inlet | No water or low pressure to the generator / cleaning | Open supply, clean filter, inlet solenoid valve |
| Service 26 | Steam generator drain | Generator will not empty | Drain valve/pump, scale blockage |
| Service 28 | Cabinet over-temperature | Safety thermostat tripped | Check fan motor, cabinet sensor, reset limiter |
| Service 29 | Electronics over-temperature | Control compartment too hot (blocked air filter, high ambient) | Clean/replace air filter, check cooling fan |
| Service 31 | Core probe | Probe defective or unplugged | Core temperature probe |
| Service 32 / 33 | Gas (gas units) | Ignition or flame failure, gas supply | Check gas supply; ignition electrode, gas valve, burner control |
| Service 34 | Data / communication | Board-to-board communication error | Cable connections, control board |
| Service 35 / 36 | Control electronics | Board fault | Control board (CPU / I/O) |
| Service 37 | Water pressure | Inlet pressure too low during operation | Supply pressure, filter, pressure reducer |
| Service 40–44 | CareControl / cleaning system | Care tabs empty, dosing or cleaning pump fault | Refill tabs; dosing pump, cleaning pump |
| Service 110 / 120 / 130 | Cleaning (iCombi) | Cleaning cycle faults on newer units | As for 10/40 series; call service if repeating |
Codes not in the table, or codes that return immediately after a reset, need a technician with the service software.
The three faults we see most in Dubai
- Service 25/37 water faults — blocked filters and scale from hard water. Fit a proper softener/filter and descale on schedule.
- Service 29 electronics overheating — units boxed into hot corners with no airflow and a clogged air filter. Clean monthly in summer.
- Service 28 over-temperature — usually a failing fan motor or a cabinet sensor drifting; both are stocked parts.
First things to try
Follow our reset guide, check water and door, then call. For parts, see Rational spare parts.
Frequently asked questions
Is a Service code the same on SCC and iCombi?
Mostly. The numbering is consistent for sensors, water and gas; cleaning-system codes changed with iCombi. When in doubt send us the code and model.
Can I clear a code myself?
Yes if the cause is simple (water off, door open, tabs empty). Sensor, board and gas codes need a technician.
Do you supply Rational parts in Dubai?
Yes: door gaskets, lamps, solenoid valves, pumps, probes, fan motors and boards for SCC and iCombi ranges, plus care tabs.